Loading
TS-M1 object-micrometer with verification certificate from Rostest for the calibration of the microscope imaging systems and linear measurements with the scale with division 0.01 mm
TS-M1 object-micrometer with verification certificate from Rostest for the calibration of the microscope imaging systems and linear measurements with the scale with division 0.01 mm
DIANEL® VISUAL MEDICAL DIAGNOSTIC SYSTEMS FROM THE MANUFACTURER

Объект-микрометр с сертификатом о калибровке поверке Ростест для калибровки систем анализа изображений. Позволяет определить размеры объектов в реальных единицах измерений. 

Объект-микрометр является средством измерения многоразового применения, срок службы средства измерения не ограничен. Срок годности Сертификата о Калибровке бессрочный. Если вам нужна более подробная информация о калибровке, рекомендуем прочитать

Features:

Width
25,4 мм
Length
76 m
All features

Stage Micrometers Slide (Stage Graticules) ideal for microscope calibration and shading correction


Accuracy: 3%
Size: 1 inch x 3 inch
Coated with a surface marked 100 divisions of 0.01 mm

Object-micrometer (Stage Micrometers Slide or Stage Graticules) is a reusable measuring instrument.

Calibration Stage Micrometer Slide is used for calibration of microscopes image analysis software for size measurement in real units. Taking pictures image micrometer scale for each working magnification and specifying a certain distance in the calibration mode, we can calculate the scale of the image in real units (micrometer, millimeter, etc.).

Micrometer is transparent glass coated with a micrometer scale with a scale division of 0.01 mm, which is equal to 10 microns.

Object-micrometer is used to calibrate both digital and simple optical microscopes, microscope calibration or verification of measurement scale is carried out both in transmitted and reflected light, luminescence, polarization, phase contrast, dark field, etc.
Dimensions micrometer object glass of 25.4 mm x 76.2 mm, which is equal to a standard glass slide razmerat used in microscopy.


Setup and Calibration.

1. Place the glass for the calibration on the object table of the microscope.
2. Select the working lens and set the maximum resolution of the camera.
3. Get clear on the screen scales the image and take a snapshot of the scale.
4. Call in the "Calibration" command using.
5. Give two clicks the beginning and end of the line and enter the value of the length of the line in real terms.
6. Enter the name of the calibration setting and save the result.
7. The program will remember the factor, and in the future you will be able to choose any unit, all the results will be recalculated in accordance with your choice.